priority-flow-control mode on the switch
On the switch, make sure priority-flow-control mode is always set to auto and flow control is
disabled.
Configuring Ethernet interfaces on Cisco switch
Always configure Ethernet interfaces on Cisco switch in trunk mode.
Binding VFC to MAC
If you are binding the VFC to MAC address in case of Cisco Nexus switch, then make sure you
make the Ethernet interface part of both Ethernet VLAN and FCoE VLAN.
Cisco nexus switch reporting “pauseRateLimitErrDisable”
If in any case the switch-port on the Cisco nexus switch is reporting
